Open air profile toughened Glass Insulator U70BP/146M
Glass insulator is a special insulation component used in overhead transmission lines to provide insulation and support for wires. High Voltage aerodynamic Insulator tempered glass insulator U70BP/146M 70kN aerodynamic GLASS INSULATOR toughened glass insulators U70BP/146M |
|
Structural composition
Glass insulators are usually composed of iron caps, tempered glass pieces, and steel feet, which are bonded together with cement adhesive.
The shape design of the aerodynamic insulator conforms to the principle of aerodynamics.
The shape and layout of the umbrella skirt can effectively reduce wind resistance, and the wind load it bears is significantly reduced compared to traditional insulators in strong wind environments. For example, the use of aerodynamic insulators on transmission lines in windy coastal areas or high mountain tuyere locations can greatly reduce the lateral wind pressure on towers.
The special shape of this insulator can also guide the air flow, so that the air flow on the surface of the insulator is more smooth. When the air flow passes by, it can quickly take away the water vapor generated on the surface of the insulator due to moisture and other reasons, and reduce the moisture on the surface of the insulator, thereby reducing the flashover risk caused by the humid environment.
Main technical parameters (GB and IEC) for open air profile toughened glass insulator | |||||||||||
Type | Diameter D(mm) | spacing H (mm) | creepage distance L(mm) | size of coupling (mm) | Mechnical failing load (kN) | Mechnical routine test (kN) | Power frequency withstand voltage DRY (kV) | Power frequency withstand voltage WET (kV) | lighting impulse withstand voltage (kV) | Min power frequency puncture voltage (kV) | Net weight per unit (kg) |
U70BP/146M | 380 | 146 | 365 | 16 | 70 | 35 | 55 | 45 | 90 | 130 | 5.3 |
U100BP/146M | 380 | 146 | 365 | 16 | 100 | 50 | 55 | 45 | 90 | 130 | 5.3 |
U120BP/146M | 380 | 146 | 365 | 16 | 120 | 60 | 55 | 45 | 90 | 130 | 5.4 |
U160BP/155M | 420 | 155 | 380 | 20 | 160 | 80 | 60 | 50 | 95 | 130 | 7.2 |
U210BP/170M | 420 | 170 | 380 | 20 | 210 | 105 | 60 | 50 | 95 | 130 | 7.3 |
U240BP/170M | 420 | 170 | 380 | 24 | 240 | 120 | 60 | 50 | 95 | 130 | 7.5 |
Product name: Glass insulator | Model number: U70BP/146M |
Material: fiberglass | Application: high voltage |
Rated voltage: 33kV | Product name: high voltage insulator |
Brand name: Huayao | Usage:Transmission lines |
Application: insulation | Rated voltage: 12kV |
Place of origin: Jiangxi, China | Certificate:ISO9001 |
Standard: IEC60383 | Color: Jade green |
Product Details
High Voltage Insulator open air profile tempered glass insulator U70BP/146M |
![]() |
Quick Detail
Glass open air profile disc Suspension Insulators U70BP/146M
Dimensions Mechanical Values Electrical Values Radio Influence Voltage Data Packing and Shipping Data |
![]() |
Huayao advantage products are glass insulators with a capacity of 40kN-550kN, which can meet the requirements of 10kV-500kV ultra-high voltage and extra high voltage transmission and transformation lines.
Huayao strictly complies with GB, ANSI, BS, DIN, AS, IEC standard designs, applicable to power transmission lines and substations.
Huayao has established a production line for ultra-high voltage tempered glass insulators with advanced production technology by introducing world-class production and testing equipment from Germany, Italy, and other countries. It has the ability to produce over 6 million pieces of AC and DC glass insulators annually.
The Production process flow:
The production process of glass insulators in Jiangxi Huayao Electric Co.,Ltd is as follows:
Mix raw material=>melt glass liquid=>press to glass insulator shape=> tempering treatment=>cold and shock test=> Glue assembly=> routine test and other test=> Finished products package.
Standard of glass insulator:
The tests have been performed in accordance with:GB/T1001.1-2021 Insulators for overhead lines with a norminal voltage above 1000V Part1: Ceramic or glass insulator units for a.c. systems Definitions, test methods and acceptance criteria (IEC 60383-1:2021 MOD)
GB/7253-2019 Insulator for overhead lines with a nominal voltage above 1000V-Ceramic or glass insulator units for a.c. systems-Characteristics of insulator units of cap and pin type (IEC 60305:2021 MOD)
IEC 60383-1:2023 Insulators for overhead lines with a norminal voltage above 1000V
IEC 60120:2020 Dimensions of ball and socket couplings of string insulator units
Jiangxi Huayao electric Co.,ltd strictly compliance with above standard. We do the factory test report as above standard.
Huayao always do following test for each products:
1.Verification of the Dimensions
2. Verifications of Displacements
3. Locking system test
4. Galvanized test
5. Thermal shock test
6. Mechanical Failing Load Test
7.Power frequency puncture withstand test

Package of the glass insulator
Standard export wooden cases Non fumigation wooden box
Customer visit: